CFT Series
Flanged Non-Retractable Injection Quill
The CFT series non-retractable design is often selected based on it's ability to handle high-pressure and/or high-temperature applications where threaded connections are not permitted. They are also ideal for applications where the strength and rigidity of the design is needed to withstand aggressive flow turbulence and high process velocities.
Minimum Required Flange Size
Tube Size | Min. Flange Size |
---|---|
1/2" | 1" |
3/4" | 1-1/2" |
1" | 1-1/2" |
1-1/2" | 2" |
2" | 2-1/2" |
2-1/2" | 3" |
3" | 4" |
4" | 6" |
DOWNLOADS
SELECTION NOTES
- Standard face to face dimension of the flanges is 8". Other lengths may be available upon request.
- Solution tube sizes listed are nominal pipe size (NPS). Schedule 40 pipe dimensions are standard. Schedule 80 is available on request, however, availability of titanium in schedule 80 is subject to change.
- Flanges are per ANSI B16.5.
- Main connection flanges (non-chemically wetted) can be stainless steel for HASTELLOY C276 and Alloy 20 solution tubes assuming stainless steel is compatible with the process fluid. Titanium flanges are required for use with titanium solution tubes.
ORDERING OPTIONS
Example: CFT-100-H-300-1-H-36-0
SERIES
TUBE SIZE
050 = 1/2"
075 = 3/4"
100 = 1"
150 = 1-1/2"
200 = 2"
250 = 2-1/2"
300 = 3"
400 = 4"
TUBE MATERIAL
H = HASTELLOY® C276
S = 316SS
A = Alloy 20
T = Titanium Gr.2
FLANGE SIZE
100 = 1"
150 = 1-1/2"
200 = 2"
250 = 2-1/2"
300 = 3"
400 = 4"
600 = 6"
800 = 8"
FLANGE CLASS
1 = 150 Class
3 = 300 Class
FLANGE MATERIAL
H = HASTELLOY® C276
S = 316SS
A = Alloy 20
T = Titanium Gr.2
INSERTION LENGTH
Specify length in inches.
TIP
0 = PVC
B = 45° Bevel
DH = Diffuser Holes
TECHNICAL NOTES
- Diffuser hole layout to be provided by customer. SAF-T-FLO does not provide recommendations for diffuser hole layouts.
HASTELLOY® C276 is a registred trademark of Haynes International.